HEAVY-DUTY CONDENSER COIL CLEANER
COIL BLAST™
High-foaming professional cleaning power for heavily contaminated outdoor condenser coils.
COBRA Coil Blast is a professional heavy-duty condenser coil cleaner designed to penetrate and loosen grease, oil, road film, soot, dirt and industrial contamination from outdoor HVAC coils. Its high-foaming action helps maintain contact with vertical coil surfaces and reach between fins, allowing loosened contamination to be removed during the required clean-water rinse. Coil Blast is aluminum safe and micro-channel safe when used as directed.
KEY BENEFITS
BUILT FOR HEAVY CONTAMINATION
Professional cleaning performance for demanding outdoor condenser-coil applications.

Heavy-Duty Cleaning
Designed for demanding outdoor condenser-coil contamination.

High-Foaming Action
Foam helps maintain contact with vertical coil surfaces and penetrate between fins.

Deep Penetration
Helps loosen embedded dirt, grease, oil, soot and accumulated deposits.

Fast Acting
Recommended dwell time of approximately 5-15 minutes.

Aluminum Safe
Suitable for aluminum condenser-coil applications when used as directed.

Micro-Channel Safe
Suitable for micro-channel condenser applications when used as directed.

Professional Grade
Developed for HVAC technicians, contractors and facility-maintenance applications.

Rinse-Clean Finish
Loosened contamination and cleaner residue are removed with a thorough clean-water rinse.

Supports Coil Performance
Routine cleaning helps maintain open airflow passages and clean heat-transfer surfaces.
RECOMMENDED APPLICATIONS
- ✓ Outdoor air-conditioning condenser coils
- ✓ Split AC outdoor units
- ✓ Packaged air-conditioning condenser coils
- ✓ Rooftop HVAC condensing units
- ✓ Air-cooled heat exchangers
- ✓ Commercial HVAC condensers
- ✓ Industrial cooling equipment
- ✓ Micro-channel condenser coils
TYPICAL CONTAMINATION
- ✓ Heavy grease
- ✓ Oil deposits
- ✓ Road film
- ✓ Soot and greasy particulate buildup
- ✓ Dust and dirt
- ✓ Atmospheric contamination
- ✓ Industrial deposits
- ✓ General outdoor coil contamination
WHY CONDENSER COIL CLEANING MATTERS
Outdoor condenser coils continuously draw ambient air across their fins and can accumulate dust, grease, fibers and environmental contamination. Buildup can restrict airflow and insulate heat-transfer surfaces.
HOW TO USE
DIRECTIONS FOR USE
- 1. Turn off and completely disconnect all electrical power to the outdoor HVAC unit before starting.
- 2. Remove loose leaves, debris or easily removable surface contamination where practical.
- 3. Spray COBRA Coil Blast directly and evenly onto the dry condenser coil, ensuring complete coverage. Use a foam-producing spray pattern for best results.
- 4. Allow the foam to remain on the coil for approximately 5-15 minutes.
- 5. Do not allow the product to dry on the treated coil surface.
- 6. Rinse thoroughly with clean water until loosened contaminants and residue are removed.
- 7. Inspect the coil, surrounding components and drainage path.
- 8. Restore electrical power only after rinsing, drainage and inspection are complete.
NOTE: Coil Blast 950ml requires rinsing. Always rinse the treated condenser coil thoroughly with clean water after the recommended dwell time.
PRODUCT DATA
TECHNICAL SPECIFICATIONS
| Brand | COBRA Professional Chemicals |
| Product | Coil Blast |
| Pack Size | 950 ml / 32 fl oz |
| Category | Heavy-Duty Condenser Coil Cleaner |
| Form | Liquid |
| Application | Finished product – direct application |
| Dilution | None required |
| Foam | High Foam |
| Dwell Time | 5-15 minutes |
| Rinse | Required – rinse thoroughly with clean water |
| Compatibility | Aluminum safe / micro-channel safe when used as directed |
| Water Solubility | Water soluble / dispersible |
| Viscosity | Low-viscosity sprayable liquid |
| Application Method | Direct spray / foam spray |
| Electrical Safety | Equipment must be switched off and isolated before application |
USAGE GUIDANCE
COMPATIBILITY & LIMITATIONS
✓ SUITABLE
- Outdoor HVAC condenser coils and air-cooled heat-transfer surfaces
- Aluminum and micro-channel coils when used as directed
- Controlled application and thorough rinsing
USE WITH CARE – SPOT TEST
- Painted surfaces
- Powder-coated surfaces
- Decorative finishes
- Plastics, rubber or surrounding materials that may receive overspray
DO NOT
- Use on energized electrical equipment
- Allow cleaner to dry on the treated surface
- Mix with acids, chlorine/bleach or other chemicals
- Use outside intended HVAC application without confirming compatibility
⚠ WARNING
SAFETY INFORMATION
Avoid skin and eye contact and avoid breathing spray mist. Wear suitable protective gloves and safety glasses or goggles during use. Keep out of reach of children. Wash hands thoroughly after handling.
- Can cause skin irritation
- Can cause serious eye irritation
- May cause an allergic skin reaction
- Disconnect electrical power before application
HANDLING
STORAGE
- ✓ Keep container tightly closed when not in use
- ✓ Store in original container in a cool, dry, shaded place
- ✓ Protect from freezing, excessive heat and prolonged direct sunlight
- ✓ Keep away from acids and incompatible chemicals
- ✓ Keep spray trigger, cap and container clean
COMMON QUESTIONS
FREQUENTLY ASKED QUESTIONS
GET COBRA COIL BLAST
HEAVY CONTAMINATION NEEDS HEAVY-DUTY CLEANING
Choose COBRA Coil Blast 950ml for professional outdoor condenser-coil maintenance. High-foaming, deep-penetrating cleaning power. Aluminum safe and micro-channel safe when used as directed.
For indoor evaporator coils, see COBRA FreshClean →